Electrical System

9-92

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

CURRENT FEED-
BACK CALIBRATION
CHECKSUM
INCORRECT

9945

1

The UGM will not permit engine

start.

The UGM will not permit any

hydraulic function operation.

The UGM has detected the current

feedback calibration checksum is

incorrect.

Power cycle.

(Replace

board)

CABIN DISPLAY
EEPROM WRITE
FAILURE

9946

1

N/A

The UGM was not able to write/

reprogram the cabin display’s

EEPROM.

Power cycle.

HARDWARE
EXCHANGE
REQUIRED

9947

1

Enter analyzer mode and take the

user directly to the “PERFORM

HARDWARE EXCHANGE?” menu.

The UGM has detected a data

mismatch between itself and the

cabin’s display.

Complete a

hardware

exchange and

cycle power.

PLATFORM
MODULE
HARDWARE
FAILURE

9948

1

The UGM will not permit engine

start from the platform.

The UGM will not permit any

hydraulic function operation from

the platform.

The platform module has detected

the cleaning current FET has failed.

Power cycle.

MACHINE
CONFIGURATION
OUT OF RANGE –
CHECK ALL
SETTINGS

9949

1

Suspend all hydraulic function,

engine, and transmission

operation.

The UGM has detected an anomaly

in the EEPROM.

Use analyzer

and correct

parameter

that is out of

range.

CABIN JOYSTICK -
INTERNAL FAILURE

9976

1

The UGM will not permit any

hydraulic function operation.

The ITT cabin joystick reports has

an internal problem. (Reference ITT

SRD)

Power cycle.

LSS CORRUPT
EEPROM

9977

1

Deactivate and inhibit the Lift Up

output.

Deactivate and inhibit the Lift Down

output.

Deactivate and inhibit the

Telescope Out output.

Deactivate and inhibit the

Telescope In output.

Deactivate and inhibit the Platform

Rotate Left output.

Deactivate and inhibit the Platform

Rotate Right output.

Deactivate and inhibit the Platform

Level Up output.

Deactivate and inhibit the Platform

Level Down output.

Deactivate platform module output

J2-19 Function Enable Relay.

Display the platform overloaded

screen on the cabin’s LCD.

At power-up or immediately

thereafter, if the PLATFORM

STATION is active and the platform

module and UGM will check the

consistency of the redundantly

stored Platform Unloaded Weight

and the Platform Maximum Allowed

Load values.

Power cycle

EEPROM VALUE –
OUT OF RANGE

9978

1

Suspend all hydraulic function and

engine operation, and command

the transmission to neutral.

The UGM has detected an anomaly

in the EEPROM.

Use analyzer

and correct

parameter

that is out of

range.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until

Advertising