Electrical system – JLG 4013PS Service Manual User Manual

Page 231

Advertising
background image

9-91

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

Electrical System

LSS EEPROM
ERROR

992

1

Power cycle.

(Replace

board)

LSS INTERNAL
ERROR – PIN
EXCITATION

993

1

Power cycle.

(Replace

board)

LSS INTERNAL
ERROR – DRDY
MISSING FROM A/D

994

1

Power cycle.

(Replace

board)

EEPROM FAILURE –
CHECK ALL
SETTINGS

998

1

Suspend all hydraulic function,

engine, and transmission

operation.

The UGM has detected an anomaly

in EEPROM.

Power cycle.

(Replace

board)

FUNCTION
LOCKED OUT –
PLATFORM
MODULE
SOFTWARE
VERSION
IMPROPER

9910

1

Suspend all hydraulic function,

engine, and transmission operation

from platform station only. (CABIN

STATION operation is permitted.)

The UGM has detected the platform

module software major revision # is

not compatible.

Reprogram

board and

power cycle.

(Replace

board)

FUNCTION
LOCKED OUT – LSS
MODULE
SOFTWARE
VERSION
IMPROPER

9911

1

Suspend all hydraulic functions,

prevent engine start, and

transmission operation from

platform station only. (CABIN

STATION operation is permitted.)

The UGM has detected the LSS

module software revision # is not

compatible (if major version is 7,

then minor will be checked to be 17

or higher; otherwise major version

higher than 7 will pass).

Reprogram

board and

power cycle.

(Replace

board)

CHASSIS TILT
SENSOR NOT GAIN
CALIBRATED

9915

1

The UGM will not permit PLAT-

FORM MODE operation.

The PLATFORM OPTION is

configured as ENABLED and the

UGM detects the tilt gain values

necessary for calculating chassis

have been lost.

Power cycle.

(Replace

board)

GROUND MODULE
FAILURE – HIGH
SIDE DRIVER
CUTOUT FAULTY

9921

1

Suspend all hydraulics.

The UGM detects a internal

hardware failure on J2-1, J2-13,

and/or J1-23.

Power cycle.

FUNCTIONS
LOCKED OUT –
MACHINE NOT
CONFIGURED

9924

1

The UGM will not permit engine

start.

The UGM will not permit any

hydraulic function operation.

The UGM detects the MACHINE

SETUP menu has never been
entered, which is noted by the

MODEL menu screen being

configured to “????????????????”

(i.e. it is the first time the board was

powered ON).

The

MACHINE

SETUP menu

has been

accessed and

power is

cycled.

CURRENT FEED-
BACK GAINS OUT
OF RANGE

9944

1

The UGM will not permit engine

start.

The UGM will not permit any

hydraulic function operation.

The UGM has detected the current

feedback gain calibrations have

been lost.

Power cycle.

(Replace

board)

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until

Advertising