Electrical system – JLG 4013PS Service Manual User Manual

Page 193

Advertising
background image

9-53

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

Electrical System

OPERATING MODE
INTERLOCK -
STABILIZERS NOT
DEPLOYED

2315

1, 15

J2-26 Engage Starter output will be

deactivated and engine start will

not be permitted if the PLATFORM

STATION is active and CABIN

MODE was the last valid operating

mode.

Changeover to PLATFORM MODE

will not be permitted. If PLAFORM

MODE is already the valid

operating state and the UGM has

not detected any chassis tilt

condition, then inhibit the Lift

function until the Boom Retracted

switch is HIGH. Once the Boom

Retracted switch is HIGH, the UGM

will permit the Lift Down

Function to operate and inhibit the

Telescope Out function. Once the

UGM detects the boom angle is

below 10°, the Telescope Out

function will be permitted and the

Lift function permitted up to a boom

angle of 10°. If the UGM detects a

chassis tilt condition with a tilt

sensor angle reading of ABSO-

LUTE TRIP POINT 1 or higher but

less than ABSOLUTE TRIP POINT

2, the above retrieval sequence will

be permitted at derated function

speeds. If the UGM detects a

chassis tilt condition with a tilt

sensor angle reading of

ABSOLUTE TRIP POINT 2 or

higher, Telescope Out will be

immediately inhibited.

The PLATFORM STATION is active

and one or both inputs J7-7 and

J7-20 are LOW.

J7-7 and J7-

20 become

HIGH.

OPERATING MODE
INTERLOCK - PLAT-
FORM NOT
ATTACHED

2316

1

J2-26 Engage Starter output will be

deactivated and engine start will

not be permitted if the PLATFORM

STATION is active and CABIN

MODE was the last valid operating

mode.

Changeover to PLATFORM MODE

will not be permitted. If

PLATFORM MODE is the last valid

operating mode, the UGM will

assume the platform is attached.

The PLATFORM STATION is active

and the UGM has not detected the

platform electrically attached.

The UGM

detects the
platform as

electrically

attached.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until

Advertising