9-63

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

Electrical System

TELESCOPE
POSITION
SWITCHES –
CONFLICTING
STATES

2558

1

Illuminate the vehicle system

distress indicator in the cabin’s

display.

Activate the buzzer for a period of 5

seconds in the cabin’s display.

Illuminate the vehicle system

distress indicator at the platform

station.

Activate the buzzer for a period of 5

seconds at the platform station.

If a platform is detected as attached

and both AM J1-4 and J7-8 are

LOW and the J3-8 Boom Retracted

input is HIGH.

Power cycled.

BOOM RETRACTED
SENSOR FAULTY –
SENSING INVALID

2560

1

Consider any information on input

J3-8 Boom Retracted invalid.

Set the system as if the boom is

always extended.

The UGM has detected one of the

following failures of the boom

retracted sensor when configured

for LSI-CAN or LSI-CAN + LMI:

With no telescope functions active,

a boom retracted sensor state

changes occur.

With Telescope In active, a boom

retracted sensor transition of HIGH

to LOW occurs.

With Telescope Out active, a boom

retracted sensor transition of LOW

to HIGH occurs.

With Telescope Out active, the
boom retracted sensor has not

HIGH for a period of 5 seconds with

at least 950mA commanded on the

function AND the Load Moment

Warning Point has been met or

exceeded.

Power cycled.

UGM OUTPUT
DRIVERS

33XXX

MAIN LIFT UP
VALVE –
OPEN CIRCUIT

33181

1

Deactivate output J2-11 Main Lift

Up Valve.

The UGM detects an open circuit at

this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

MAIN LIFT VALVES
– SHORT TO
BATTERY

33182

1

Deactivate output J2-11 Main Lift

Up Valve.

Deactivate output J2-22 Main Lift

Down Valve.

Decouple/disable current feedback
input J3-2 Lift Return (Disables Lift

Up and Down).

The UGM detects a short to battery

at this output.

Power cycled.

MAIN LIFT UP
VALVE – SHORT TO
GROUND

33183

1

Deactivate output J2-11 Main Lift

Up Valve.

Decouple/disable current feedback
input J3-2 Lift Return (Disables Lift

Up and Down).

The UGM detects a short to ground

at this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until