Electrical system – JLG 4013PS Service Manual User Manual

Page 194

Advertising
background image

Electrical System

9-54

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

OPERATING MODE
INTERLOCK -
CHASSIS NOT
LEVEL

2317

1, 16

J2-26 Engage Starter output will be

deactivated and engine start will

not be permitted if the PLATFORM

STATION is active and CABIN

MODE was the last valid operating

mode.

Changeover to PLATFORM MODE

will not be permitted. If

PLATFORM MODE is already the

valid operating state and a chassis

tilted condition occurs from a tilt

sensor angle reading of

ABSOLUTE TRIP POINT 1or

higher but less than ABSOLUTE

TRIP POINT 2, the Lift and

Telescope function speeds will be

derated if an ENGINE RUNNING

condition exists and APU operation

will be permitted if an ENGINE

STOPPED condition exists. If

PLATFORM MODE is already the

valid operating state and a chassis

tilted condition occurs from a tilt

sensor angle reading of

ABSOLUTE TRIP POINT 2 or

higher, telescope out will be

inhibited.

The PLATFORM STATION is active

and the UGM has detected the

machine’s chassis is not sufficiently

level for platform operation.

The UGM

detects the

machine’s

chassis tilt

level is within

range.

OPERATING MODE
INTERLOCK -
BOOM ANGLE TOO
HIGH

2318

1

J2-26 Engage Starter output will be

deactivated and engine start will

not be permitted if the PLATFORM

STATION is active and CABIN

MODE was the last valid operating

mode.

Changeover to PLATFORM MODE

will not be permitted.

Changeover to CABIN MODE will

not be permitted.

CABIN MODE was the last valid

operating mode and the PLAFORM

STATION is currently active and the

UGM has detected the boom angle

is 10°.

PLATFORM MODE was the last

valid operating mode and the

CABIN

STATION is currently active and the

UGM has detected the boom angle

is 10°.

The UGM has

detected the

boom angle is

10°.

OPERATING MODE
INTERLOCK -
BOOM NOT FULLY
RETRACTED

2319

1

J2-26 Engage Starter output will be

deactivated and engine start will

not be permitted if the PLATFORM

STATION is active and CABIN

MODE was the last valid operating

mode.

Changeover to PLATFORM MODE

will not be permitted.

Changeover to CABIN MODE will

not be permitted.

CABIN MODE was the last valid

operating mode and the PLAFORM

STATION is currently active and the

UGM has detected J3-8 Boom

Retracted is LOW.

PLATFORM MODE was the last

valid operating mode and the

CABIN

STATION is currently active and the

UGM has detected J3-8 Boom

Retracted is LOW.

The UGM has

detected J3-8

Boom

Retracted is

HIGH.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until

Advertising