Electrical system – JLG 4013PS Service Manual User Manual

Page 200

Advertising
background image

Electrical System

9-60

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

CABIN JOYSTICK –
LEFT ROLLER
FAULT

2350

1

Left roller function requests will be

ignored by the UGM.

The CAT cabin joystick detects a

fault with the left roller on the

joystick.

Power cycled.

CABIN JOYSTICK –
RIGHT ROLLER
FAULT

2351

1

Right roller function requests will be

ignored by the UGM.

The CAT cabin joystick detects a

fault with the right roller on the

joystick.

Power cycled.

CABIN JOYSTICK –
TRIGGER SWITCH
FAULT

2352

1

Trigger switch requests will be

ignored by the UGM.

The CAT cabin joystick detects a

fault with the trigger switch on the

joystick.

Power cycled.

BOOM ANGLE
SENSOR –
INTERNAL FAILURE

2353

1

Display the fixed boom angle value

of ‘99’ on the operator’s cabin

display.

Temporarily assign a fixed boom

angle value of 99×.

Disallow boom angle sensor
calibration (“BOOM ANGLE:

CALIBRATION FAIL”).

Ignore all hydraulic function

requests from the platform module.

Deactivate and inhibit the Lift Up

output if the platform is detected as

attached or PLATFORM MODE is

the current active mode; otherwise,

derate the MAX LIFT UP in the

PERSONALITIES menu screen by

the LIFT UP DERATE value in the

Constant Data tables.

The UGM or platform module has

detected one of the following

internal failures of the CAN based

boom angle sensor:

A difference of more than 7 counts

(2.5

°

) for 1 second between the 2

angle readings.

A CAN bus message indicating a
boom angle value out of range of

the calibration, i.e. more than 250

counts.

Power cycled.

OPERATING
INTERLOCK –
ATTACHMENT
COUPLING PIN NOT
ENGAGED

2354

1

J2-26 Engage Starter output will be

deactivated and engine start will

not be permitted if the PLATFORM

STATION is active and CABIN

MODE was the last valid operating

mode.

Changeover to PLATFORM MODE

will not be permitted.

If the PLATFORM MODE is the

valid operating mode, Lift and

Telescope functions will be derated

to the LIFT UP DERATE and TELE

DERATE values in Constant Data.

The platform module has detected

J1-1 of the platform module is LOW

and the PLATFORM STATION is

active and a platform is detected as
attached and CAN communications

exist between the UGM and plat-

form module.

J1-1 of the

platform

module goes

HIGH for a
period of 3

seconds.

OPERATING
INTERLOCK –
PLATFORM NOT
COUPLED

2384

1

J2-26 Engage Starter output will be

deactivated and engine start will

not be permitted if the PLATFORM

STATION is active and CABIN

MODE was the last valid operating

mode.

Changeover to PLATFORM MODE

will not be permitted. If

PLATFORM MODE is the last valid

operating mode, the UGM will

assume the platform is attached.

The PLATFORM STATION is active

and a MARKET configuration of

AUSTRAILIA exists and the UGM

has not detected the platform
coupled signal on input J3-13

(LOW).

The UGM

detects the
platform as

coupled for 2

seconds.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until