Electrical system – JLG 4013PS Service Manual User Manual

Page 226

Advertising
background image

Electrical System

9-86

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

CANBUS FAILURE –
BOOM RIDE/BOOM
FLOAT MODULE

6631

1

If active, deactivate and then inhibit

operation of Boom Ride Valve,

Boom Float Valve, and Boom Tank

Valve.

The UGM has lost communications

with the Boom Ride/Boom Float

(Accessory) Module.

Power cycled.

CANBUS FAILURE -
BOOM EXTENSION
LIMIT MODULE

6637

1

The UGM has lost communications

with the Accessory Module.

Power cycled.

CANBUS FAILURE -
LSI

6638

1

If active, the control system will
respond as if the Load Moment

Cutout % parameter has been

reached (regardless of the state of

input J4-10) and react accordingly

depending on the MARKET

configuration.

The UGM has lost communications

with the LSI system for 1000

milliseconds.

Power cycled.

TILT SENSOR

81XXX

CHASSIS TILT
SENSOR NOT
CALIBRATED

813

1

The UGM will not permit

PLATFORM MODE operation.

The PLAFORM OPTION is

configured as ENABLED and the

UGM detects its on-board tilt sensor

has not been calibrated.

Successful tilt

calibration has

been com-

pleted.

CHASSIS TILT
SENSOR OUT OF
RANGE

814

1

The UGM will not permit

PLATFORM MODE operation.

The PLAFORM OPTION is

configured as ENABLED and the

UGM detects a platform is attached
and the UGM detects the tilt sensor

reading is more than 19° for 4

seconds and the PLATFORM

STATION is active or the CABIN

STATION is active with one or more

stabilizer deployed.

Power cycle.

(Replace

board)

CHASSIS TILT
SENSOR
DISAGREEMENT

815

1

The UGM will not permit

PLATFORM MODE operation.

The PLATFORM OPTION is

configured as ENABLED and the

UGM detects a platform is attached

and the UGM detects the machine

is driving and a 3° difference

between tilt sensor for 5 seconds or

the UGM detects the machine is not

driving and a 1° difference between

tilt sensor for 2 seconds.

Power cycle.

(Replace

board)

PLATFORM LOAD
SENSE

82XXX

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until

Advertising