Electrical system – JLG 4013PS Service Manual User Manual

Page 189

Advertising
background image

9-49

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

Electrical System

APU SWITCH INPUT
INVALID – INPUT
HIGH AT POWER
UP

2116

1

Still allow APU function request.

If J7-4 Boom Angle reading is less

than 10° and the J3-8 Boom

Retracted input is HIGH, cutout the

Main Lift Up and Telescope Out

functions.

If a platform is configured as

ENABLED and the UGM detects

J4-16 Auxiliary Power Unit (APU)

Enable is HIGH at system power up.

The input

goes LOW for

a period of at

least 1

second.

PLATFORM
JOYSTICK NOT IN
NEUTRAL
POSITION AT
POWER UP

2117

1

Ignore platform lift and telescope

function requests from the platform

joystick.

If the PLATFORM STATION is

active and a platform is configured

as ENABLED and a platform is

detected as attached and the

platform joystick is not detected to

be in the neutral position at system

power up.

Joystick is

detected to be

in neutral

position.

ENGINE
PRE-HEAT
PREVENTED –
INPUT HIGH AT
POWER UP

2118

1

Ignore engine pre-heat function

request.

If the UGM detects J4-20 Engine

Pre-Heat or the platform module

input J1-23 Engine Pre-heat is

HIGH at system power up.

The input

goes LOW for

a period of at

least 1

second.

FRAME LEVEL
RIGHT INPUT –
INVALID SIGNAL

2119

1

Deactivate and inhibit J2-5 Frame

Level Right Valve.

Deactivate and inhibit J2-7 Frame

Level Left Valve.

Deactivate and inhibit J1-3

Stabilizer and Frame Level Speed

Valve (if applicable) as it relates to

frame leveling functions only.

If J4-17 Frame Leveling Right is

HIGH at power up.

Power cycled.

FRAME LEVEL
LEFT INPUT –
INVALID SIGNAL

2120

1

Deactivate and inhibit J2-5 Frame

Level Right Valve.

Deactivate and inhibit J2-7 Frame

Level Left Valve.

Deactivate and inhibit J1-3

Stabilizer and Frame Level Speed

Valve (if applicable) as it relates to

frame leveling functions only

.

If J4-9 Frame Leveling Left is HIGH

at power up.

Power cycled.

HYDRAULIC QUICK
CONNECT INPUT –
INVALID
SIGNAL

2121

1

Deactivate output J1-23 Hydraulic

Quick Connect Valve.

Ignore hydraulic quick connect

function requests

.

Deactivate output J2-9 Auxiliary

Function-A Valve until the cabin’s

joystick is in the neutral position

and the S4 switch is OFF and J1-23

is confirmed to be deactivated.

Deactivate output J2-20 Auxiliary
Function-B Valve until the cabin’s

joystick is in the neutral position

and the S4 switch is OFF and J1-23

is confirmed to be deactivated.

If hydraulic quick connect feature is

configured in the MACHINE SETUP

menu and J7-35 Hydraulic Quick

Connect ON is HIGH at power up or

J3-10 Hydraulic Quick Connect

OFF is LOW at power up or J7-35

matches the state of input J3-10 for

0.5 seconds.

Power cycled.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until