Electrical system – JLG 4013PS Service Manual User Manual

Page 201

Advertising
background image

9-61

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

Electrical System

ERRATIC
PLATFORM
COUPLED SIGNAL

2385

1

The platform will be considered

coupled.

The UGM detects three signal
transitions on J3-13 within a 5

second period.

Power cycled.

LOSS OF
PLATFORM
COUPLED SIGNAL

2386

1

N/A

The CABIN STATION is active and

a MARKET configuration of

AUSTRALIA exists and J3-13

Platform Coupled input is LOW and

J1-21 Platform Attached input is

LOW or valid platform module CAN

bus messages are being

continuously received by the UGM

or “ERRACTIC PLATFORM

ATTACHED SIGNAL” fault exists.

Power cycled.

FUNCTION
PREVENTED

25XXX

MODEL CHANGED
– HYDRAULICS
SUSPENDED –
CYCLE EMS

259

1

Deactivate and inhibit all hydraulic

function operation.

J2-26 Engage Starter output will be

deactivated and engine start will

not be permitted.

The MODEL selection on the

Analyzer was changed from its

previous setting.

Power cycled.

FUNCTIONS
LOCKED OUT –
CONSTANT DATA
VERSION
IMPROPER

2520

1

Deactivate and inhibit all hydraulic

function operation.

J2-26 Engage Starter output will be

deactivated and engine start will

not be permitted.

The Constant Data code version is

not up to date / compatible with the

current machine Application code.

Proper

Constant

Version is

loaded and

power is

cycled.

ENGINE START
PREVENTED –
PARK BRAKE NOT
SET

2525

1

J2-26 Engage Starter output will be

deactivated and engine start will

not be permitted.

The CABIN STATION is active and

J4-8 Engine Start input is HIGH and

J4-5 Park Brake is LOW (not set).

J4-5 Park

Brake is HIGH

(set).

BOOM EXTENDED
SWITCH –
CONFLICTING
STATE

2526

1

N/A

J7-8 Boom Extension Limit input is

LOW, the feature is enabled in the

MACHINE SETUP menu, and the

J3-8 Boom Retracted input is HIGH.

Power cycled.

EXCESSIVE BOOM
ANGLE FOR
HYDRAULIC QUICK
CONNECT
OPERATION

2527

1

Not activate outputs J2-9 Auxiliary

Function-A Valve or J2-20 Auxiliary

Function-B Valve.

If hydraulic quick connect feature is

configured in the MACHINE SETUP

menu and the boom angle sensor

reading is 10° and the boom angle

sensor has successfully completed

a calibration and a hydraulic quick

connect function request is

detected.

J7-35

Hydraulic

Quick

Connect ON

is LOW and

J3-10

Hydraulic

Quick

Connect OFF

is HIGH.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until

Advertising