2 fault code table, Fault code table, Electrical system 9.18.2 fault code table – JLG 4013PS Service Manual User Manual

Page 187

Advertising
background image

9-47

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

Electrical System

9.18.2

Fault Code Table

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until

HELP COMMENT

00XXX

EVERYTHING OK

001

The system detects no problems

exist.

POWER UP

21XXX

POWER CYCLE

211

Power was cycled ON.

FUNCTION ENABLE
INPUTS – INVALID
SIGNAL STATES

214

1

Ignore and inhibit all function

requests from the platform station.

Output J2-19 Function Enable

Relay of the platform module will be

deactivated.

Output J2-26 Engage Starter will

be deactivated and inhibited from

the platform.

If both J7-15 of the UGM and J7-8

of the platform module are

simultaneously HIGH or LOW for a

period of 1 second after the

Function Enable Relay power-up

check have been successfully

completed or J7-15 is HIGH and

J7-8 is LOW after the Function

Enable Relay power-up check have

been successfully completed and

the PLATFORM STATION is active

and a valid PLATFORM MODE

exists.

Power cycled.

JOYSTICK AXES
NOT IN NEUTRAL
POSITION AT
POWER UP

215

1

Ignore command signals from the

joystick regarding the X axis and Y

axis.

At system power-up, if the one of

the two axes are not in the neutral

position, the UGM will report and

log a “JOYSTICK AXES NOT IN

NEUTRAL POSITION AT

POWER-UP” fault.

A CAN

message is

received

indicating the

X axis and Y

axis are in the

neutral

position.

JOYSTICK ROLLER
NOT IN NEUTRAL
POSITION AT
POWER UP

216

1

Ignore command signals from the

joystick regarding the roller.

At system power-up, if the roller is

not in the neutral position on JLG

models only.

A CAN

message is

received

indicating the
roller is in the

neutral

position.

JOYSTICK S1
BUTTON ACTIVE AT
POWER UP

217

1

Ignore command signals from the

joystick S1 button that was active

during the power-up.

At system power-up, if the S1 button

is activated.

A CAN

message is

received

indicating the

joystick S1

button is not

activated.

JOYSTICK S2
BUTTON ACTIVE AT
POWER UP

218

1

Ignore command signals from the

joystick S2 button that was active

during the power-up.

At system power-up, if the S2 button

is activated on JLG models only.

A CAN

message is

received

indicating the

joystick S2

button is not

activated.

Advertising