3. Advanced Commands

Receive (acknowledge)

Start

\xfe

Projector address

\x01

Command[0]

\x00

Command[1]

\x06

Checksum

\x07

Stop

\xff

3.2.12

PiP remove Layout

Description

Removes a PiP layout.

Command

Command [0]

\x12

Command [1]

\x0a

Data

strPipname1

...

strPipnameN

The strPipnameN string is of the C-language type. see chapter "1. Serial communications Basics", "Syntax",
page 9

Wildcards can be used to specify strPipnameN.see "Syntax", page 9

Example

Removes the PiP layout “test”.

Transmit

Start

\xfe

Projector address

\x01

Command[0]

\x12

Command[1]

\x0a

Data[0]

\x74

Data[1]

\x65

Data[2]

\x73

Data[3]

\x74

Data[4]

\x00

Checksum

\xdd

Stop

\xff

Receive (acknowledge)

Start

\xfe

Projector address

\x01

R5976884 RLM SERIES 04/04/2006