30 maximum gamma, read, Basic commands – Barco RS232 User Manual

Page 42

Advertising
background image

2. Basic Commands

Returned Data

Data [0] = minimum Gamma value

Example

Reads the minimum Gamma value of the projector, the awnser being

\x10

Transmit

Start

\xfe

Projector address

\x01

Command[0]

\x26

Command[1]

\x70

Checksum

\x97

Stop

\xff

Receive (acknowledge)

Start

\xfe

Projector address

\x01

Command[0]

\x00

Command[1]

\x06

Checksum

\x07

Stop

\xff

Receive (Answer)

Start

\xfe

Projector address

\x01

Command[0]

\x26

Command[1]

\x70

Data [0]

\x10

Checksum

\xa7

Stop

\xff

2.7.30

Maximum Gamma, Read

Description

Reads the Maximum (range) Gamma value of the projector

Command

Command [0]

\x27

Command [1]

\x70

Returned Data

Data [0] = Maximum Gamma value

Example

Reads the Maximum Gamma value of the projector, the awnser being

\x1c

40

R5976884 RLM SERIES 04/04/2006

Advertising