3. Advanced Commands

Returned Data

Data [0] = min/max value

3.26 Automatic Gain Control interval, Write

Description

Sets the AGC to short or long.

Command

Command [0]

\x20

Command [1]

\x9c

Data

Data [0] = byte type

byte value:

0 = short ; 1 = long

Example

Sets the AGC interval to “short”

Transmit

Start

\xfe

Projector address

\x01

Command[0]

\x20

Command[1]

\x9c

Data[0]

\x00

Checksum

\xbd

Stop

\xff

Receive (acknowledge)

Start

\xfe

Projector address

\x01

Command[0]

\x00

Command[1]

\x06

Checksum

\x07

Stop

\xff