24 gain control, increment/decrement, 25 minimum/maximum agc value, read, 138 3.25 minimum/maximum agc value, read – Barco RS232 User Manual

Page 140: Gain control, increment/decrement, Minimum/maximum agc value, read

Advertising
background image

3. Advanced Commands

Receive (acknowledge)

Checksum

\x07

Stop

\xff

Receive (awnser)

Start

\xfe

Projector address

\x01

Command[0]

\x21

Command[1]

\xa2

Data[0]

\x0a

Data[1]

\x00

Checksum

\xce

Stop

\xff

3.24 Gain Control, Increment/Decrement

Description

Increments/decrements the Gain Control value by one

Commands

increment:

Command [0]

\x22

Command [1]

\xa2

decrement:

command[0]

\x23

command[1]

\xa2

3.25 Minimum/Maximum AGC value, Read

Description

Reads the minimum/maximum AGC(Automatic Gain Control) value.

Commands

read minimum:

Command [0]

\x26

Command [1]

\xa2

read maximum:

Command[0]

\x27

Command[1]

\xa2

138

R5976884 RLM SERIES 04/04/2006

Advertising