2. Basic Commands

Command

Command [0]

\x21

Command [1]

\x03

Returned Data

Data [0] =Saturation value

Example

Reads the actual Saturation value of the projector, the awnser being

\x20

Transmit

Start

\xfe

Projector address

\x01

Command[0]

\x21

Command[1]

\x03

Checksum

\x25

Stop

\xff

Receive (acknowledge)

Start

\xfe

Projector address

\x01

Command[0]

\x00

Command[1]

\x06

Checksum

\x07

Stop

\xff

Receive (Answer)

Start

\xfe

Projector address

\x01

Command[0]

\x21

Command[1]

\x03

Data [0]

\x20

Checksum

\x45

Stop

\xff

2.7.17

Minimum Saturation, Read

Description

Reads the minimum (range) Saturation value of the projector

Command

Command [0]

\x26

Command [1]

\x03

R5976884 RLM SERIES 04/04/2006