2. Basic Commands

Receive (acknowledge)

Start

\xfe

Projector address

\x01

Command[0]

\x00

Command[1]

\x06

Checksum

\x07

Stop

\xff

Receive (Answer)

Start

\xfe

Projector address

\x01

Command[0]

\x21

Command[1]

\x0d

Data [0]

\x00

Data [1]

\x1e

Checksum

\x4d

Stop

\xff

2.30.5

Lamp runtime, Read

Description

Reads the lamp runtime, the lamp (lamp1 or lamp2) runtime to be read is given in the data field.

Command

Command [0]

\x64

Data

Data[0] = unsigned byte:

data value: 1 = lamp1 ; 2 = lamp2

Returned Data

Data[0] = unsigned byte (1 = lamp1 ; 2 = lamp2)

unsigned double word (4 bytes) representing the runitme : see chapter "1. Serial communications Basics", "Data words", page 6

Data[1] = msb

Data[2]

Data[3]

Data[4] = lsb

2.30.6

Lamps Serial number, Read

Description

Reads the Lamps Serial number, the lamp (lamp1 or lamp2) to be read is given in the data field.

66