2. Basic Commands

Example

Reads the actual Phase value of the projector, the awnser being

\x1a

Transmit

Start

\xfe

Projector address

\x01

Command[0]

\x21

Command[1]

\x06

Checksum

\x28

Stop

\xff

Receive (acknowledge)

Start

\xfe

Projector address

\x01

Command[0]

\x00

Command[1]

\x06

Checksum

\x07

Stop

\xff

Receive (Answer)

Start

\xfe

Projector address

\x01

Command[0]

\x21

Command[1]

\x06

Data [0]

\x1a

Checksum

\x42

Stop

\xff

2.7.35

Minimum Phase, Read

Description

Reads the minimum (range) Phase value of the projector

Command

Command [0]

\x26

Command [1]

\x06

Returned Data

Data [0] = minimum Phase value

Example

Reads the minimum Phase value of the projector, the awnser being

\x00