1 blanking reset, 2 blanking enable, write, 3 blanking enable, read – Barco RS232 User Manual

Page 82: 80 2.41.2 blanking enable, write, 80 2.41.3 blanking enable, read, Blanking reset, Blanking enable, write, Blanking enable, read

Advertising
background image

2. Basic Commands

2.41.1

Blanking Reset

Description

Allows the reset of the blanking values.

Command

Command [0]

\x17

Data

byTypeBlanking : 1 byte describing the type of blanking.

Data [0] = 0 : blanking done and saved in the image file

Data [0] = 1: blanking done on the display

The maximum number of pixels which can be blanked depends on the native resolution of the panels

2.41.2

Blanking enable, Write

Description

Enables the blanking.

Command

Command [0]

\x20

Command [1]

\x56

Data

Data[0] = byTypeBlanking

Data[0] = 0 : blanking on image file

Data[0] = 1: blanking on display

Data[1] = unsigned byte

Data[1] = 0 : disable

Data[1] = 1 : enable

2.41.3

Blanking enable, Read

Description

Reads whether the blanking is enabled.

Command

Command [0]

\x21

Command [1]

\x56

Sent Data

byTypeBlanking : one byte describing the type of blanking

Data [0] = 0 : blanking on image file (saved in image file)

Data [0] = 1 : blanking on display

Returned Data

Data[0] = byTypeBlanking

Data[0] = 0 : blanking on image file

Data[0] = 1: blanking on display

Data[1] = unsigned byte

80