3. Advanced Commands

Sent Data

Data[0] = bySlaveAddr1

Data[1] = bySlaveAddr2

...

Data[N-1] = bySlaveAddrN

bySlaveAddrn = byte representing the address of the module or unit to be diagnosed.

If ommited, all all the units are reported.

Unit

Hex address

Motor driver

\x74

Lamp driver

\x78

Video processor

\x96

Fpga backplane1

\xb4

Fpga backplane2

\xb6

Fpga backplane3

\xb8

ADC 9886 layer1

\x98

ADC 9887 layer1

\x9e

ADC 9887 layer2

\x9a

DVI indicators layer1

\x7e

DVI indicators layer2

\x7a

Video decoder

\x42

Video indicators

\x7c

Table 3-286
address overview

Returned Data

Data[0] = strDiagnosis1

Data[1] = strDiagnosis2

...

Data[N-1] = strDiagnosisN

3.33 Panel size, Read

Description

Reads the size of the LCD panels

Command

Command [0]

\xf0

Command [1]

\x01

Returned Data

Data [0]...Data [3] = wpixels = unsigned word,see chapter "1. Serial communications Basics", "Data words", page 6 , representing
the number of pixels in one line.

Data [4]...Data [7] = wlines = unsigned word (2bytes), representing the number of lines.