5 minimum contrast, read, 6 maximum contrast, read, Minimum contrast, read – Barco RS232 User Manual

Page 26: Maximum contrast, read, Basic commands

Advertising
background image

2. Basic Commands

2.7.5

Minimum Contrast, Read

Description

Reads the minimum (range) contrast value of the projector

Command

Command [0]

\x26

Command [1]

\x01

Returned Data

Data [0] = minimum contrast value

Example

Reads the minimum contrast value of the projector, the awnser being

\x00

Transmit

Start

\xfe

Projector address

\x01

Command[0]

\x26

Command[1]

\x01

Checksum

\x28

Stop

\xff

Receive (acknowledge)

Start

\xfe

Projector address

\x01

Command[0]

\x00

Command[1]

\x06

Checksum

\x07

Stop

\xff

Receive (Answer)

Start

\xfe

Projector address

\x01

Command[0]

\x26

Command[1]

\x01

Data [0]

\x00

Checksum

\x28

Stop

\xff

2.7.6

Maximum Contrast, Read

Description

Reads the Maximum (range) contrast value of the projector

24

R5976884 RLM SERIES 04/04/2006

Advertising