Installation, Electrical installation terminal assignment – Lenze E82ZAFPC010 User Manual

Page 29

Advertising
background image

Installation

Electrical installation

Terminal assignment

5

l

29

EDS82ZAFPC010 EN 4.0

E82ZAFPC010 function module

GND1

GND1

B

7

20

59

+20V

A

28

39

7

GND2

X3.1

X3.2

X3.3

T/R(A)

T/R(B)

E82ZAFP011

Terminal
X3.1/

Designation

Function / level

+

PES

Additional HF shield termination

A

T/R(A)

RS485 data line A

B

T/R(B)

RS485 data line B

Terminal
X3.2/

Designation

Function / level

59

External DC voltage supply for the function module

l

+24 V DC

± 10% (reference: GND1)

l

Current consumption on 24 V DC: 80 mA

The current for looping through the supply voltage to other nodes via
terminal 59 must be max. 3 A.

7

GND1

Reference potential for X3.3/20

Terminal
X3.3/

Designation

Function / level

7

GND1

Reference potential for X3.3/20

39

GND2

Reference potential for controller inhibit (CINH) at X3.3/28

28

CINH

Controller inhibit

l

Input resistance: 3.3 k

W

l

Start = HIGH (+12 ... +30 V)

l

Stop = LOW (0 ... +3 V)
(reference: GND2)

20

DC voltage source for external supply of controller inhibit (CINH)

l

+20 V (reference: GND1)

l

I

max

= 10 mA