9 diagnostics, 1 led status displays, Diagnostics – Lenze E82ZAFPC010 User Manual

Page 67: Led status displays, 9diagnostics

Advertising
background image

Diagnostics

LED status displays

9

l

67

EDS82ZAFPC010 EN 4.0

9

Diagnostics

9.1

LED status displays

1

ON

A

A

B

B

CN VP

7

40

39 28 20 59 7

+

2

1

E82ZAFP00x

2

1

E82ZAFP010

E82ZAFP004

E82ZAFP008

LED

Description

Pos.

Colour

Condition

1

yellow

off

No communication with the PROFIBUS master.

blinking

Communication with the PROFIBUS master has been established via the
function module.

2

green

off

l

The function module is not supplied with voltage.

l

The standard device and/or the external voltage supply is switched off.

blinking

The function module is supplied with voltage but is not connected to the
standard device.
Causes:

l

The standard device is switched off.

l

The standard device is in the initialisation phase.

l

The standard device is not available

on

The function module is supplied with voltage and is connected to the
standard device.

1

+

2

yellow/
green

blinking

Internal function module error

Advertising