2 parameter set transfer, Parameter set transfer, Parameter data transfer – Lenze E82ZAFPC010 User Manual

Page 66

Advertising
background image

Parameter data transfer

Parameter set transfer

8

l

66

EDS82ZAFPC010 EN 4.0

8.2

Parameter set transfer

Lenze parameter sets

The 8200 vector and 8200 motec controllers have 2/4 parameter sets, whose parameters
can directly be addressed with the PROFIBUS.

)

Note!

ƒ

Parameter set 1 can be accessed via ...
– DRIVECOM parameter data channel
– PROFIdrive parameter data channel (DP−V0)
– PROFIdrive parameter data channel (DP−V1)

ƒ

Parameter sets 2 ... 4 can be accessed via ...
– DRIVECOM parameter data channel
– PROFIdrive parameter data channel (DP−V1)

Addressing of Lenze parameter sets

The parameter sets are addressed by means of a code offset:

ƒ

Offset 0 addresses parameter set 1 (C0000 ... C1999).

ƒ

Offset 2000 addresses parameter set 2 (C2000 ... C3999).

ƒ

Offset 4000 addresses parameter set 3 (C4000 ... C5999).

ƒ

Offset 6000 addresses parameter set 4 (C6000 ... C7999).

If a parameter is only available once (see documentation for 8200 vector), use the code
offset 0.

Example for C0011 (maximum rotating−field frequency):

ƒ

C0011 in parameter set 1: Lenze code number = 11

ƒ

C0011 in parameter set 2: Lenze code number = 2011

ƒ

C0011 in parameter set 3: Lenze code number = 4011

ƒ

C0011 in parameter set 4: Lenze code number = 6011

Parameter set transfer with keypad

)

Note!

Always switch the mains after you have transferred the parameter sets with
the keypad!
Observe the options for parameter set transfer with keypad marked with
"Keypad

ð

" under code C0002.

If an address is assigned via C1509, the address must be reassigned via the parameter data
channel after a parameter set transfer. Afterwards mains switching is required. The
address modified via keypad becomes effective immediately.