Codes

Communication−relevant Lenze codes

10

l

73

EDS82ZAFPC010 EN 4.0

C1511:
Configuration of process output data

Code

Subcode

Index

Possible settings

Data type

Lenze

Selection

C1511

23064

d

=

5A18

h

FIX32

1 (POW1)

17

see table below

2 (POW2)

3

3 (POW3)

4

4 (POW 4)

5

5 (POW 5)

6

6 (POW 6)

7

7 (POW 7)

8

8 (POW 8)

9

9 (POW 9)

10

10 (POW 10)

11

The process data output words (POW) of the master can be freely assigned to bit control
commands or setpoints of the controller via C1511.

Selection

Scaling

1

FIF control word 1 (FIF−CTRL1)

16 bits

2

FIF control word 2 (FIF−CTRL2)

16 bits

3

Setpoint 1 (NSET1−N1)

±24000

º ±480 Hz

4

Setpoint 2 (NSET1−N2)

±24000

º ±480 Hz

5

Additional setpoint (PCTRL1−NADD)

±24000

º ±480 Hz

6

Actual process controller value (PCTRL1−ACT)

±24000

º ±480 Hz

7

Process controller setpoint (PCTRL1−SET1)

±24000

º ±480 Hz

8

Reserved

9

Torque setpoint/torque limit value (MCTRL1−MSET)

2

14

º100 % rated motor torque

10

PWM voltage (MCTRL1−VOLT−ADD)

(
For special applications only.

^ System manual for 8200 vector

11

PWM angle (MCTRL1−PHI−ADD)

12

Reserved

13

FIF−IN.W1

16 bits or 0 ... 65535

14

FIF−IN.W2

16 bits or 0 ... 65535

15

FIF−IN.W3

0 ... 65535

16

FIF−IN.W4

0 ... 65535

17

DRIVECOM control word (DRIVECOM−CTRL)

16 bits