Codes, Communication−relevant lenze codes, C1510: configuration of process input data – Lenze E82ZAFPC010 User Manual

Page 72

Advertising
background image

Codes

Communication−relevant Lenze codes

10

l

72

EDS82ZAFPC010 EN 4.0

C1510:
Configuration of process input data

Code

Subcode

Index

Possible settings

Data type

Lenze

Selection

C1510

23065

d

=

5A19

h

FIX32

1 (PIW1)

18

See table below

2 (PIW2)

3

3 (PIW3)

4

4 (PIW 4)

5

5 (PIW 5)

6

6 (PIW 6)

7

7 (PIW 7)

8

8 (PIW 8)

9

9 (PIW 9)

10

10 (PIW 10)

11

The bit status information or the actual values of the controller can be freely assigned to
the max. 10 process data input words (PIW) of the master.

Selection

Scaling

1

FIF status word 1 (FIF−STAT1)

16 bits

2

FIF status word 2 (FIF−STAT2)

16 bits

3

Output frequency with slip (MCTRL1−NOUT+SLIP)

±24000

º ±480 Hz

4

Output frequency without slip (MCTRL1−NOUT)

±24000

º ±480 Hz

5

Apparent motor current (MCTRL1−IMOT)

2

14

º 100 % rated device current

6

Actual process controller value (PCTRL1−ACT)

±24000

º ±480 Hz

7

Process controller setpoint (PCTRL1−SET)

±24000

º ±480 Hz

8

Process controller output (PCTRL1−OUT)

±24000

º ±480 Hz

9

Controller load (MCTRL1−MOUT)

±2

14

º±100 % rated motor torque

10

DC−bus voltage (MCTRL1−DCVOLT)

16383

º 565 V DC for 400 V mains

16383

º 325 V DC for 230 V mains

11

Ramp function generator input (NSET1−RFG1−IN)

±24000

º ±480 Hz

12

Ramp function generator output (NSET1−NOUT)

±24000

º ±480 Hz

13

FIF−OUT.W1

16 bits or 0 ... 65535

14

FIF−OUT.W2

16 bits or 0 ... 65535

15

FIF−OUT.W3

0...65535

16

FIF−OUT.W4

0...65535

17

DRIVECOM control word (DRIVECOM−CTRL)

16 bits

18

DRIVECOM status word (DRIVECOM−STAT)

16 bits

Advertising
This manual is related to the following products: