1 adapting device controls, Adapting device controls – Lenze E82ZAFPC010 User Manual

Page 38

Advertising
background image

Commissioning

Configuring the host system (master)
Adapting device controls

6

l

38

EDS82ZAFPC010 EN 4.0

6.3.1

Adapting device controls

ƒ

Lenze device control
– Set C1511/1 (POW1) = 1

ð FIF control word 1 (FIF−CTRL1)

– Set C1510/1 (PIW1) = 1

ð FIF status word 1 (FIF−STAT1)

ƒ

Device control via DRIVECOM
– Set C1511/1 (POW1) = 17

ð DRIVECOM control word (DRIVECOM−CTRL)

– Set C1510/1 (PIW1) = 18

ð DRIVECOM status word (DRIVECOM−STAT)

For detailed information about the configuration of process data, see chapter "Process
data transfer",

^ 43)

I

Tip!

Use overall consistency

ƒ

Please observe that the processing of consistent data varies between hosts.
This must be taken into account in the PROFIBUS application program.

ƒ

A detailed description of consistency can be found in the appendix (

86)