3 drivecom status word, Drivecom status word, Process data transfer – Lenze E82ZAFPC010 User Manual

Page 53

Advertising
background image

Process data transfer

DRIVECOM control

DRIVECOM status word

7

l

53

EDS82ZAFPC010 EN 4.0

7.2.3

DRIVECOM status word

Bit

Meaning

0

Device status "Ready to switch on"

0
1

Status less than "Ready to switch on"
Status at least "Ready to switch on"

1

Device status "Switched on"

0
1

Status less than "Switched on"
Status at least "Switched on"

2

Device status "Operation enabled"

0
1

Status less than "Operation enabled"
Status "Operation enabled"

3

Device status "Fault"

0
1

No fault (TRIP)
Fault (TRIP) active

4

Status "Inhibit voltage" command

0
1

Command applied
Command not applied

5

Status "Quick stop (QSP)" command

0
1

Command applied
Command not applied

6

Device status "Switch−on inhibit"

0
1

Status "Switch−on inhibit" not active
Status "Switch−on inhibit" active

7

Collective warning

0
1

No warning
Warning (overtemperature) active

8

Collective message
Automatic setting and resetting of pulse inhibit (IMP) in the device status "Operation enabled".
Possible causes: Undervoltage, overvoltage or overcurrent

0
1

No message
Message IMP active

9

Bus access right

1 Always

10

Status speed/frequency deviation

0
1

RFG

on

tu RFG

off

RFG

on

= RFG

off

11

0

Status DRIVECOM speed limitation
Always

12

Mapping of FIF status word 1 (FIF−STAT1), bit 0 (DCTRL1−PAR−B0)

13

Mapping of FIF status word 2 (FIFSTAT2), bit 0 (DCTRL1−PAR−B1)

14

Mapping of FIF status word 1 (FIFSTAT1), bit 2 (MCTRL1−IMAX)

15

Mapping of FIF status word 1 (FIF−STAT1), bit 5 (PCTRL1−QMIN)

Advertising
This manual is related to the following products: