Codes – Lenze E82ZAFPC010 User Manual

Page 85

Advertising
background image

Codes

Important controller codes

10

l

85

EDS82ZAFPC010 EN 4.0

ƒ

Transferring parameter sets with the keypad:

Selection

Important

You can use the keypad to transfer parameter sets to other controllers.
During the transfer, access to the parameters via other channels will be inhibited!

Keypad

ð controller

Overwrite all available parameter sets (PAR1 ... PAR4, FPAR1 if
available) with the corresponding keypad data

70

With function module

10

(other)
Keypad

ð PAR1 (+ FPAR1)

Overwrite the selected parameter set and, if available, FPAR1
with the corresponding keypad data

71

With function module

11

(other)
Keypad

ð PAR2 (+ FPAR1)

72

With function module

12

(other)
Keypad

ð PAR3 (+ FPAR1)

73

With function module

13

(other)
Keypad

ð PAR4 (+ FPAR1)

74

With function module

14

(other)
Controller

ð keypad

Copy all available parameter sets (PAR1 ... PAR4, FPAR1 if
available) into the keypad

80

With function module

20

(other)
Keypad

ð function module

Overwrite only the module−specific parameter set FPAR1 with
the keypad data

40

Only with function module
Function module

ð keypad

Copy only the module−specific parameter set FPAR1 into the
keypad

50

Only with function module

ƒ

Saving your own setting:

Selection

Important

9

PAR1

ð own setting

You can store your own setting for the controller parameters
(e.g. the delivery state of your machine):
1. Check that parameter set 1 is active
2. Inhibit the controller
3. Set C0003 = 3, confirm with

v

4. Set C0002 = 9, confirm with

v, your own setting has

been stored

5. Set C0003 = 1, confirm with

v

6. Enable the controller

This function can also be used to copy PAR1 to the parameter
sets PAR2 ... PAR4

5

Own setting

ðPAR1

Restore your own setting in the selected parameter set

6

Own setting

ðPAR2

7

Own setting

ðPAR3

8

Own setting

ðPAR4

Advertising