Process data transfer – Lenze E82ZAFPC010 User Manual

Page 50

Advertising
background image

Process data transfer

Lenze device control
Process input data configuration

7

l

50

EDS82ZAFPC010 EN 4.0

FIF status word 1 (FIF−STAT1)

FIF status word 2 (FIF−STAT2)

Bit

Assignment

Bit

Assignment

0

Current parameter set bit 0

(DCTRL1−PAR−B0)

0

Current parameter set bit 1

(DCTRL1−PAR−B1)

0
1

Parameter set 1 or 3 active
Parameter set 2 or 4 active

0
1

Parameter set 1 or 2 active
Parameter set 3 or 4 active

1

Pulse inhibit

(DCTRL1−IMP)

1

TRIP, Q

min

or pulse inhibit active

(DCTRL1−TRIP−QMIN−IMP)

0
1

Power outputs enabled
Power outputs inhibited

0
1

False
True

2

I

max

limit

(MCTRL1−IMAX)

(If C0014 = 5: Torque setpoint)

2

PTC warning active

(DCTRL1−PTC−WARN)

0
1

Not reached
Reached

0
1

False
True

3

Output frequency = frequency setpoint

(DCTRL1−RFG1=NOUT)

3

Reserved

Do not write to this bit!

0
1

False
True

4

Ramp function generator input 1 = ramp function
generator output 1

(NSET1−RFG1−I=O)

4

C0054 < C0156 and Q

min

threshold reached

(DCTRL1−(IMOT<ILIM)−QMIN)

0
1

False
True

0
1

False
True

5

Q

min

threshold

(PCTRL1−QMIN)

5

C0054 < C0156 and NSET1−RFG1−I=O

(DCTRL1−(IMOT<ILIM)−RFG−I=O)

0
1

Not reached
Reached

0
1

False
True

6

Output frequency = 0

(DCTRL1−NOUT=0)

6

LP1 warning (fault in motor phase) active

(DCTRL1−LP1−WARN)

0
1

False
True

0
1

False
True

7

Controller inhibit

(DCTRL1−CINH)

7

f < f

min

(NSET1−C0010 ... C0011)

0
1

Controller enabled
Controller inhibited

0
1

False
True

11...8

Device status

(DCTRL1−STAT*1 ... STAT*8)

8

TRIP active

(DCTRL1−TRIP)

Bit 11 10 9

8

0
1

False
True

0
0

0
0

0
1

0
0

Controller initialisation
Switch−on inhibit

9

Motor is running

(DCTRL1−RUN)

0
0

0
1

1
0

1
0

Operation inhibited
Flying−restart circuit active

0
1

False
True

0

1

0

1

DC−injection brake active

10

Motor is running clockwise

(DCTRL1−RUN−CW)

0
0

1
1

1
1

0
1

Operation enabled
Message active

0
1

False
True

1

0

0

0

Fault active

11

Motor is running counter−clockwise

(DCTRL1−RUN−CCW)

1

1

1

1

Communication with basic device not
possible

0
1

False
True

12

Overtemperature warning

(DCTRL1−OH−WARN)

12

Reserved

0
1

No warning
J

max

− 10

C reached

13

DC−bus overvoltage

(DCTRL1−OV)

13

Reserved

0
1

No overvoltage
Overvoltage

14

Direction of rotation

(DCTRL1−CCW)

14

C0054 > C0156 and NSET1−RFG1−I=0

(DCTRL1−(IMOT>ILIM)−RFG−I=O)

0
1

CW rotation
CCW rotation

0
1

False
True

15

Ready for operation

(DCTRL1−RDY)

15

Reserved

0
1

Not ready for operation (fault)
Ready for operation (no fault)

Tab. 7−2

Parameter structure FIF status word (FIF−STATx)