2 standard assembly with fixing brackets, Installation – Lenze 8240 HVAC Series User Manual

Page 26

Advertising
background image

Installation

4-2

UOOuhäáã~_^NMMO

4.1.2

Standard assembly with fixing brackets

Assembly preparations for 822X EëÉÉ cfd QJNF
To assemble and install the controller it is necessary to remove the unit

cover. The accessory kit inside the controller contains the parts required

for the assembly and installation.

1.Loosen screws (x).
2.Swing cover to the top and detach.
3.Bolt the fixing brackets onto the housing.

hPRKMNPN

 N 

3 )

cfd QJN

aáãÉåëáçåë J лн~еЗ~кЗ ~ллЙгДду

3)

With attachable fieldbus or I/O module:
Observe assembly depth and assembly space required for connection cables

[mm]

a

b

b1

c

c1

d

d1

e

3)

e1

g

k

m

8221 / 8222 / 8223

250

402

350

22

206

370

24

250

230

6.5

24

11

8224

340

580

510

28.5

283

532

38

285

265

11

24

18

8225

340

672

591

28.5

283

624

38

285

265

11

28

18

8226 / 8227

450

748.5 680

30.5

389

702

38

285

265

11

28

18

8241 / 8242

78

384

350

39

-

365

-

250

230

6.5

30

-

8243 / 8244

97

384

350

48,5

-

365

-

250

230

6.5

30

-

8245 / 8246

135

384

350

21.5

92

365

-

250

230

6.5

30

-

Show/Hide Bookmarks