L-force | plc designer – Lenze PLC Designer PLC Designer (R3-1) User Manual
Page 283

L-force | PLC Designer
Menu Commands sorted by Categories
DMS 4.1 EN 03/2011 TD29
281
Routers:
Abb. 104 Dialog Gateway - Routers
In the edit field at right of Max Routers you may enter an upper limit for the number of
routers. Activating the checkbox Enable parallel routing allows the direct
communication of two different networks sharing a common node, that, however, is
represented twice and bears a different address in each network. While sending a
message from one network two the other one via the common node the addressing
will be mapped from one to the other configuration when passing this node.
In the window below all routers together with their subnets and interfaces are
displayed. Basically each interface is put under control of an own Router that is part of
the Main Net. However, to save resources, it is possible to add (up to 15) further
interfaces to one router, not at the same level though, but within subnets that are
displayed in an own folder below the router.