L-force | PLC Designer
General Editors
754
DMS 4.1 EN 03/2011 TD29
Forcing of variables
In addition to the possibility to enter a prepared value for a variable within the
declaration of any editor the ST-Editor provides to click on the monitoring box of a
variable within the implementation part (in online mode), whereon you may enter the
prepared value in the rising dialogue:
Abb. 418 Dialog - Prepare Value
You find the name of the variable completed by its path within the device tree
("Expression"), its type and current value. By activating the corresponding item you
may choose wether you want to
• prepare a new value which has to be entered in the edit field thereby
• remove a prepared value
• release the variable actually forced
• release the variable actually forced and reset it to the value it was assigned to just
before forcing
The selected action will be carried out on executing the menu command Force Values
(item Online) or pressing F7.