This dialog will only be provided on a tab of an EtherCAT Slave configuration editor, if 
the Expert Settings mode for the slave is activated. 
Here for the particular slave you can define parameters for the device, which will be 
transferred by SDOs (Service Data Objects) at startup of the system. The dialog will be 
provided only if the device supports "CAN over EtherCAT". The object dictionary 
containing the necessary data objects either is included in the EtherCAT XML 
description file or it is available in an EDS-file which is referenced in the XML 
description file. 
Abb. 496 Startup parameters dialog
 
CAN over EtherCAT 
To add an SDO entry to the configuration table, use button New... 
The dialog Select item from object dictionary will open which offers the available 
object dictionary entries as defined in the EDS-file. 
Abb. 497 Dialog - Select item from object dictionary