L-force | plc designer – Lenze PLC Designer PLC Designer (R3-1) User Manual

Page 708

Advertising
background image

L-force | PLC Designer

General Editors

706

DMS 4.1 EN 03/2011 TD29

Abb. 386 Example - Online view of a IL program

In online view ladder networks have animated connections: Connections with value
TRUE are displayed in bold blue, connections with value FALSE in bold black, whereas
connections with no known value or with an analog value are displayed in standard
outline (black and not fat). (Remark: the values of the connections are calculated from
the monitoring values. It is no real powerflow.)

Abb. 387 Example - Online view of a LD program

Notice for the online view of a POU of type function block: In the implementation part
no values will be viewed in the monitoring windows but "<Value of the expression>"
and the inline monitoring fields in the implementation part will show three question
marks each.