L-force | plc designer – Lenze PLC Designer PLC Designer (R3-1) User Manual
Page 412

L-force | PLC Designer
Menu Commands sorted by Categories
410
DMS 4.1 EN 03/2011 TD29
Prepare Value Dialog
Abb. 200 Prepare Value dialog
This dialog is used to prepare a new value for a variable, to remove a prepared value, to
release a forced variable or to release it and additionally reset its value to the one the
variable was assigned to before forcing.
The dialog will open if you click in the 'Prepared Value' field of a currently forced value
or in the inline monitoring field of the variable in the implementation part of the
FBD/LD/IL-editor.
The following information on the currently concerned variable is displayed:
Expression: path of the variable: for example "PLC.Application.PLC_PRG.ivar"
Type: data type, for example "DWORD"
Current value: for example "TRUE" or "23"