Pioneer Gas Monitor Operator’s Manual

Installation and Start Up • 15

Connecting the DC Power Source

WARNING: Verify that the power source is unplugged or turned off at the power source

end before you continue with this procedure.

Perform the following procedure to connect the DC power source to the Pioneer.

NOTE:

A jumper block located at the middle upper edge of the main circuit board
allows you to configure the Pioneer to operate from either 12 VDC

or

24 VDC.

To select 12 VDC operation

(input range of 11 to 22 VDC), install the jumper

block over the right two pins.

To select 24 VDC operation

(input range of 23 to

60 VDC), install the jumper block over the left two pins. The factory default

configuration is for 24 VDC operation.

1.

Open the housing door, and locate the bottom external wiring terminal strip (TB2).
See Figure 2-1, Pioneer Gas Monitor Component Location, to assist you in locating the
bottom external wiring terminal strip.

2.

Guide a DC power cord through one of the conduit hubs on the bottom of the Pioneer
housing.

CAUTION:

Do not route power and detector wiring through the same conduit hub. The power

wiring may disrupt the transmission of the detector signal to the monitor.

3.

Connect the DC line to the lower row of terminals on the external wiring terminal
strip as shown in Figure 3-4.

Figure 3-4: DC Power Wiring

Connecting External Alarms

Perform the following procedure to connect external alarms to the Pioneer.

NOTE:

The analyzer card includes external alarm connections that are dedicated to the
applicable channel only. See Appendix B, Gas Detectors, to wire external alarms

to the analyzer card.

1.

Open the housing door, and locate the external wiring terminal strips (TB2 and TB3).
See Figure 2-1, Pioneer Gas Monitor Component Location, to assist you in locating the
external wiring terminal strips.

2.

Guide the wiring of the external alarm through one of the conduit hubs on the bottom
of the Pioneer housing.

1
2

+

DC Power
Source

External Wiring
Terminal Strip (TB2)

-