Pioneer Operator’s Manual (PRELIMINARY)
Oxygen Transmitter • 1
Oxygen Transmitter
Overview
This detection insert describes the oxygen transmitter. This insert also describes how to
install, start up, maintain, and calibrate the transmitter and run the Channel Setup
program. A parts list at the end of this insert lists replacement parts and accessories for the
oxygen transmitter.
Specifications
Table 1 lists specifications for the oxygen transmitter. See the specifications in Chapter 1,
Introduction, for specifications that apply to the Pioneer Gas Monitor.
Table 1: Specifications
Target Gas
Oxygen (O
2
)
Sampling Method
Diffusion
Signal Output
4 to 20 mA
Detection Range
0 to 25.0% VOL (by volume)*
Alarm 1 Setpoint
19.5% VOL (decreasing)*
Alarm 2 Setpoint
17.0% VOL (decreasing)*
Alarm 3 Setpoint
23.5% VOL (increasing)*
Response Time
90% in 30 seconds
*
These specifications represent RKI standard settings; however, you can adjust them in the Channel Setup program.