Front panel and character lcd – RKI Instruments GD-70D Series User Manual

Page 10

Advertising
background image

1 Overview

1-4. Names and functions for each part

GD-70D

- 10 -

<Front Panel and Character LCD>





























①

MODE key

Used to enter the maintenance mode.
It is also used to cancel or skip in a specific mode.

②

TEST/SET key

Used to enter the test mode.
It is used for value confirmation and so on in a specific mode.

③

▲ key

Used to switch screen or change a value (UP).

④

▼ key

Used to switch screen or change a value (DOWN).

⑤

Lock lever

Lever to lock the main unit. Push it to attach or detach the main unit.

⑥

Sensor unit nameplate
display window

Window to look at the nameplate of the sensor unit.
You can identify the currently attached sensor unit.

⑦

Power lamp (POWER)

Power lamp. It lights in green when the power is on.

⑧

First alarm lamp
(ALM1)

First alarm lamp. It lights in red when the first alarm is reached.

⑨

Second alarm lamp
(ALM2)

Second alarm lamp. It lights in red when the second alarm is reached.

⑩

Fault lamp (FAULT)

Fault lamp. It lights in yellow when an abnormality is detected in the detector.

⑪

Gas name display

Displays the gas name in chemical formula and so on (e.g. Silane = SIH4).

⑫

Concentration value
display

Displays the gas concentration and so on.

⑬

Unit display

Displays the unit according to the specification (ppm, ppb, vol%, %, %LEL).

⑭

Concentration bar
indicator

The detectable range (full scale = FS) is divided into 20 with bars. The
increase in concentration is displayed in proportion to the full scale.

⑮

Alarm setpoint
indicator

The alarm setpoints (AL1 and AL2) are indicated on the concentration bar.

⑯

Flow rate indicator

Displays the suction flow rate. The center of the bars means the normal
suction flow rate of 0.5 L/min.

⑰

Communication
indicator

For GD-70D-NT, this indicator is displayed while transmitting data with the
upper unit (TX, RX).

⑱

Maintenance indicator

Displayed during the maintenance mode. When this indicator is displayed,
the alarm contact is disconnected to be disabled.

⑲

Inhibit indicator

Displayed when the inhibition (point skip) is set.

⑳

Pyrolyzer unit
connection indicator

Displayed when the dedicated pyrolyzer unit (PLU-70) is connected.

c

MODE key

d

TEST/SET key

e

▲key

f

▼key

g

Lock lever

h

Sensor unit nameplate display window

i

Power lamp

j

First alarm lamp

k

Second alarm lamp

l

Fault lamp

⑪

Gas name display

⑫

Concentration

value display

⑬

Unit display

⑭

Concentration

bar indicator

⑮

Alarm setpoint

indicator

⑯

Flow rate

indicator

⑰

Communication

indicator

⑱

Maintenance

indicator

⑲

Inhibit indicator

⑳

Pyrolyzer unit

connection indicator