Front panel and character lcd – RKI Instruments GD-70D Series User Manual

Page 10

Advertising
background image

1 Overview

1-4. Names and functions for each part

GD-70D

- 10 -

<Front Panel and Character LCD>





























MODE key

Used to enter the maintenance mode.
It is also used to cancel or skip in a specific mode.

TEST/SET key

Used to enter the test mode.
It is used for value confirmation and so on in a specific mode.

▲ key

Used to switch screen or change a value (UP).

▼ key

Used to switch screen or change a value (DOWN).

Lock lever

Lever to lock the main unit. Push it to attach or detach the main unit.

Sensor unit nameplate
display window

Window to look at the nameplate of the sensor unit.
You can identify the currently attached sensor unit.

Power lamp (POWER)

Power lamp. It lights in green when the power is on.

First alarm lamp
(ALM1)

First alarm lamp. It lights in red when the first alarm is reached.

Second alarm lamp
(ALM2)

Second alarm lamp. It lights in red when the second alarm is reached.

Fault lamp (FAULT)

Fault lamp. It lights in yellow when an abnormality is detected in the detector.

Gas name display

Displays the gas name in chemical formula and so on (e.g. Silane = SIH4).

Concentration value
display

Displays the gas concentration and so on.

Unit display

Displays the unit according to the specification (ppm, ppb, vol%, %, %LEL).

Concentration bar
indicator

The detectable range (full scale = FS) is divided into 20 with bars. The
increase in concentration is displayed in proportion to the full scale.

Alarm setpoint
indicator

The alarm setpoints (AL1 and AL2) are indicated on the concentration bar.

Flow rate indicator

Displays the suction flow rate. The center of the bars means the normal
suction flow rate of 0.5 L/min.

Communication
indicator

For GD-70D-NT, this indicator is displayed while transmitting data with the
upper unit (TX, RX).

Maintenance indicator

Displayed during the maintenance mode. When this indicator is displayed,
the alarm contact is disconnected to be disabled.

Inhibit indicator

Displayed when the inhibition (point skip) is set.

Pyrolyzer unit
connection indicator

Displayed when the dedicated pyrolyzer unit (PLU-70) is connected.

c

MODE key

d

TEST/SET key

e

▲key

f

▼key

g

Lock lever

h

Sensor unit nameplate display window

i

Power lamp

j

First alarm lamp

k

Second alarm lamp

l

Fault lamp

Gas name display

Concentration

value display

Unit display

Concentration

bar indicator

Alarm setpoint

indicator

Flow rate

indicator

Communication

indicator

Maintenance

indicator

Inhibit indicator

Pyrolyzer unit

connection indicator