7 Regular Maintenance Mode

- 57 -

GD-70D

↓ ↑

● ○ ○

SET 10

FLT PTRN

MAINTENANCE

SET 10. FLT PTRN

This is a setting screen of the
fault alarm activation. Do not
change the setting when the
detector is used in a normal
way, because it determines
how the detector functions.
(Auto-reset setting: "nL")

↓ ↑

● ○ ○

SET 11

AT FLOW

MAINTENANCE

SET

ON

AT FLOW

MAINTENANCE

↓↑

OFF

AT FLOW

MAINTENANCE

SET 11.AT FLOW

Set the flow rate
auto-adjustment.
Select either ON/OFF, and
then press the SET key to
confirm the selection.
When ON is selected, the
flow rate auto-adjustment is
activated.

| ↑

| |

↓ |

● ○ ○

SET 12

ZERO F

MAINTENANCE

SET

ON

ZERO F

MAINTENANCE

↓↑

OFF

ZERO F

MAINTENANCE

SET 12. ZERO F

Set the zero follower when
the electrochemical type
(ESU) or the
pyrolysis-particle type (SSU)
is installed.
Select either ON/OFF, and
then press the SET key to
confirm the selection.
When ON is selected, the
zero follower function is
activated.
* When SSU is installed, you
must select ON.

| ↑

| |

↓ |

● ○ ○

SET 13

ZERO 24F

MAINTENANCE

SET 13.ZERO 24F

This is a supplemental setting
screen for the above zero
follower function. (A setting to
determine whether the
first-24-hour zero follower will
be performed after the power
is turned on.)
Do not change the setting
when the detector is used in a
normal way.
(ON setting)

| ↑

| |

↓ |

● ○ ○

SET 14

S ASSIST

MAINTENANCE

SET

ON

S ASSIST

MAINTENANCE

↓↑

SET 14.S ASSIST

Set the sensitivity correction
when the electrochemical
type (ESU) is installed.
Select either ON/OFF, and
then press the SET key to
confirm the selection.
When ON is selected, the
sensitivity correction function
is activated.

| ↑

| |

↓ |

OFF

S ASSIST

MAINTENANCE