8 Maintenance

8-2. Gas calibration method

GD-70D

- 66 -

<Span Adjustment "2-2">

This is used to perform the span adjustment. For the oxygen deficiency alarm specification (OSU - 0 - 25
vol%), this is the same as "1-1".

Span Adjustment Display

PW

A1

A2

F LCD

2-2.SPAN

Press the SET key.

● ○ ○ ○

2-2

SPAN

MAINTENANCE

Gas Introduction

Introduce a gas, and then press the SET
key when the reading is stabilized.
* In case of less than 10%FS, this is not
switched to the next menu.

● ○ ○ ○

2.0ppm

SPAN GAS

MAINTENANCE

● ○ ○ ○

8.0ppm

SPAN VAL

MAINTENANCE

Span Adjustment

Because the reading will be fixed, select
the introduced gas concentration by
pressing the ▲ or ▼ key. Select the
number, and then press the SET key.
(20.9 vol% in the oxygen deficiency alarm
specification)

Span Adjustment Completed

● ○ ○ ○

8.0ppm

SPAN OK

MAINTENANCE

Adjustment result record

To record the adjustment result, press the
SET key.
(Press the MODE key to cancel this menu.)

● ○ ○ ○

8.0ppm

SPAN Y/N

MAINTENANCE

Adjustment Completed

The menu returns to 2-2.SPAN
automatically.

● ○ ○ ○

8.0ppm

SPAN END

MAINTENANCE

Return to 2-2.SPAN

* When the span adjustment fails

● ○ ○ ○

8.0ppm

SPAN NG

MAINTENANCE

Return to 2-2.SPAN

CAUTION

Do not press the
SET key before the
reading is stabilized.

CAUTION

Exhaust gas must be collected
in the exhaust bag or discharged
through the exhaust line.