2 Installation

2-3. How to wire

- 25 -

GD-70D

<How to Connect to Terminal Plate>

When cables are connected to the connectors, use the dedicated
lever or a flathead screwdriver to do it as shown below.














NOTE

How to Use the Dedicated Handling Lever









To check whether the wire is connected securely, pull the wire
gently. (Do not pull the wire strongly.)


<How to Clamp Cables>


Insert the supplied fastening-band to the hole on the
wall-mounted unit as shown in the figure. Position the band so
that its coarse side faces the wire. After inserting the
fastening-band, fix the wire together.

NOTE

When an optional cable ground is used, it must
be attached to the external wiring hole.






CAUTION

• The right tools must be used.

• In principal, one wire can be connected to one wiring

hole.

• When the wire is inserted into the driver slot by mistake, it

does not contact the conductive part. This may cause
defective electrification or heating.

• When the wire is inserted under the spring by mistake, it

does not contact the conductive part. This may cause
defective electrification or heating.

Push the dedicated
handling lever to
open the terminals,
into which you can
insert wires (one wire
to one terminal).

Push the lever with your
finger to lower the spring
in its inside.

While holding down the
lever, insert the wire into the
(round) wiring hole until it
reaches the deepest point.
Once the lever is released,
the wire is secured.

Position the
band so that
its coarse
side faces the
wire.