Bus active (ba) status indicator, Bus voltage (ul) status indicator(1), Bus active (ba) status indicator 7-3 – Rockwell Automation 20-COMM-I Interbus Adapter User Manual

Page 87: Bus voltage (ul) status indicator

Advertising
background image

Troubleshooting

7-3

(1)

Only visible when drive cover is open.

Bus Active (BA) Status Indicator

Status

Cause

Corrective Actions

Off

Bus not active.

• Set master to start data transmission.

Solid Green

Bus active, exchanging
data.

• No action.

Flash Green

Bus active, but no data
exchange.

• Set master to start data transmission.

Bus Voltage (UL) Status Indicator

(1)

Status

Cause

Corrective Actions

Off

Bus voltage is not OK.

• Securely connect the adapter to the drive

using the Internal interface cable

• Apply power to the drive.

Solid Green

Bus active.

• No action.

20COMM-UM007A-EN-P.book Page 3 Tuesday, January 22, 2002 10:52 AM