Rockwell Automation 20-COMM-I Interbus Adapter User Manual

Page 97

Advertising
background image

Adapter Parameters

B-3

09

[DPI I/O Active]
I/O that the adapter is actively transmitting. The
value of this parameter will usually be equal to the
value of Parameter 8 - DPI I/O Config.

Default:

xxx0 0001

Bit Values:

0 = I/O disabled
1 = I/O enabled

Type:

Read Only

Bit Definitions
0 = Cmd/Ref
1 = Datalink A
2 = Datalink B
3 = Datalink C
4 = Datalink D
5 = Not Used
6 = Not Used
7 = Not Used

10

[Flt Cfg Logic]
Sets the Logic Command data that is sent to the
drive if any of the following is true:

• Parameter 06 - [Comm Flt Action] is set to

Send Flt Cfg and communications are
disrupted.

The bit definitions will depend on the product to
which the adapter is connected.

Default:

0000 0000 0000 0000

Minimum:

0000 0000 0000 0000

Maximum:

1111 1111 1111 1111

Type:

Read/Write

Reset Required:

No

11

[Flt Cfg Ref]
Sets the Reference data that is sent to the drive if
any of the following is true:

• Parameter 06 - [Comm Flt Action] is set to

Send Flt Cfg and communications are
disrupted.

Default:

0

Minimum:

0

Maximum:

4294967295

Type:

Read/Write

Reset Required:

No

Important: If the drive uses a 16-bit
Reference, the most significant word of this
value must be set to zero (0) or a fault will
occur.

12
13
14
15
16
17
18
19

[Flt Cfg A1]
[Flt Cfg A2]
[Flt Cfg B1]
[Flt Cfg B2]
[Flt Cfg C1]
[Flt Cfg C2]
[Flt Cfg D1]
[Flt Cfg D2]
Sets the data that is sent to the Datalink in the
drive if any of the following is true:

• Parameter 06 - [Comm Flt Action] is set to

Send Flt Cfg and the communications are
disrupted.

Default:

0

Default:

0

Default:

0

Default:

0

Default:

0

Default:

0

Default:

0

Default:

0

Minimum:

0

Maximum:

4294967295

Type:

Read/Write

Reset Required:

No

Important: If the drive uses 16-bit
Datalinks, the most significant word of this
value must be set to zero (0) or a fault will
occur.

20

PIDD W0 Cfg
Configured Process Input Data Description for
Word 0. PCP Object to use for Word 0 transmitted
to Interbus master.

Default:

0x2F9A

(Logic Status)

Setting:

See

Table B.1

Type:

Read/Write

Reset Required:

No (becomes active

when Interbus network
is restarted)

21

PIDD W0 Actual
Actual Process Input Data Description for Word 0.

Value:

See

Table B.1

Type:

Read Only

Parameter
No. Name and Description

Details

Bit

Default

1

0

0

0

0

x x

x

0

1

2

3

4

5

7

6

20COMM-UM007A-EN-P.book Page 3 Tuesday, January 22, 2002 10:52 AM