Specifications

Overview

This appendix contains general and environmental specifications and
certifications for the FLEX I/O Thermocouple, RTD, mV Input Modules.

General Specifications

Attribute

Value

Number of inputs

8 channels (2 groups of 4)

Module location

Cat. Nos. 1794-TB3G, 1794-TB3GS, 1794-TB3GK Terminal

base units

Nominal input voltage

ranges

-40…100 mV DC for thermocouples

0…325 mV for RTDs

mV default

Supported

thermocouple types

Type

B

E

J

K

TXK/XK(L)

N

R

S

T

Range °C

300…1800 °C

-270…1000 °C

-210…1200 °C

-270…1372 °C

200…800 °C

-270…1300 °C

-50…1768 °C

-50…1768 °C

-270…400 °C

Range °F

(572…3272 °F)

(-454…1832 °F)

(-346…2192 °F)

(-454…2502 °F)

(-328…1472 °F)

(-454…2372 °F)

(-58…3214 °F)

(-58…3214 °F)

(-454…752 °F)

Supported RTD types

Resistance

100

Ω

Pt

α

= 0.00385 Euro -200…870 °C (-328…1598 °F)

200

Ω

Pt

α

= 0.00385 Euro -200…400 °C (-328…752 °F)

100

Ω

Pt

α

= 0.003916 U.S. -200…630 °C (-328…1166 °F)

100

Ω

Pt

α

= 0.003916 U.S. -200…400 °C (-328…752 °F)

100

Ω

Nickel -60…250 °C (-76…482 °F)

200

Ω

Nickel -60…200 °C (-76…362) °F)

120

Ω

Nickel -80…320 °C (-112…608 °F)

10

Ω

Copper -200…260 °C (-328…470 °F)

Resolution

14 bits

Accuracy vs. filter cutoff

0.05% of full range in millivolt mode with filtering selected

Hardware only = 0.10% of full range in millivolt mode

Data format

°C (implied decimal point XXX.X)

°F (implied decimal point XXX.X)

°K (implied decimal point XXX.X)

-32767…32767

0…65535

0…5000 ohms mode (implied decimal point XXX.X)

-4000…+10000 millivolt mode (implied decimal

point XXX.XX)

Common mode rejection

-80 db @ 5V peak-to-peak, 50…60 Hz

Common mode input range +15V min