Data Transfer File Instructions

Chapter 11

11-17

When the rung becomes:

True - The data of a word is transferred from your file to your designated
word address.

False - No action is taken.

ATTENTION: The counter address for the word-to-file move
and file-to-word move instructions should be used only for the
intended instruction and the corresponding instructions which
manipulate the accumulated value. Do not inadvertently
manipulate the preset or accumulated word. Changes to these
values could result in unpredictable machine operation or a run
time error. Damage to equipment and/or injury to personnel
could occur.

Keystrokes: You enter a file to word move by performing the
following steps.

[FILE]

12

The screen does not change.

FileĆToĆWord Move

Counter Addr:

Position:

File Length:

30

001

001

DN

File A:

Word Addr:

010

110-110

030

15

0

Start

Parameters: The procedure for entering parameters for a file to word move
is the same as the procedure for a file to file move.

In this chapter, we have showed you three data transfer file instructions.
Also, we showed you how to use the data monitor display. The next
chapter shows you three types of sequencer instructions.

Chapter Summary