Sequencers

Chapter 12

12-7

Insert the following values. The cursor moves automatically throughout
the sequencer instruction. The values are:

COUNTER ADDR: 200
CURRENT STEP: 001
SEQ LENGTH: 006
WORDS PER STEP: 2
FILE: 400
MASK: 070
INPUT WORDS:
1:110 2: 201

The completed instruction should look like this:

200

001

006

2

400Ć 413

070Ć 071

1: 110

3: 4:

Sequencer Input

Counter Addr:

Current Step:

Seq Length:

Words Per Step:

File:

Mask:
Input Words

2. 201

For this example, enter data using the binary data monitor mode. Get your
data from the worksheet (Figure 12.4). A filled in block means that a 1
should be inserted in the corresponding bit position.

EN

Sequencer Output

Counter Addr:

Current Step:

Seq Length:

030

000

001

DN

Words Per Step:

File:

Mask:

2

110- 110

010Ć 010

030

17

030

15

Output Words

1: 010

3: 4:

200

001

006

2

400Ć 413

070Ć 071

1: 110

3: 4:

Sequencer Input

Counter Addr:

Current Step:

Seq Length:

Words Per Step:

File:

Mask:
Input Words

2. 201 2.