Quick Reference

Appendix C

CĆ9

Table C.H

Counter Instructions

NOTE: The counter word address, XXX, is assigned to the counter accumulated area of the data table. To determine which addresses are

valid accumulated areas, the most significant digit in the word address must be an even number.

Bit 14 is the overflow/underflow bit.

Bit 15 is the count complete bit.

Bit 16 is the enable bit for the CTD instruction.

Bit 17 is the enable bit for the CTU instruction.

The word address displayed will be 3 or 4 digits long depending on the data table size. When entering the word address, use a leading

zero if necessary.

Key Symbol

Instruction Name

1770-T3 Display

Rung Conditions

Status Bits

-(CTU)-

Up Counter

XXX

-(CTU)-

PR YYY

AC ZZZ

Each time the rung goes true, the

accumulated value is incremented

one count. The counter will

continue counting after the preset

value is reached.
The accumulated value can be

reset by the CTR instruction.

When the rung is true:

bit 14-set if AC>999

bit 15-set when AC>PR PR

bit 17-set
When the rung is false:

bits 14-15-retained if it was set

bit 17-reset

-(CTR)-

Counter Reset

XXX

-(CTR)-

PR YYY

AC ZZZ

XXX-Word address of the CTU is

resetting.
The preset and accumulated

values are automatically entered by

the industrial terminal.
When the rung is true, the CTU or

CTD accumulated value and

status bits are reset to 000.

When the rung is true:

bits 14-17-reset
When the rung is false: No action

is taken

-(CTD)-

Down Counter

XXX

-(CTD)-

PR YYY

AC ZZZ

Each time the rung goes true, the

accumulated value is decreased by

one count.

When the rung is true:

bit 14-set when AC<000

bit 15-set when AC<PR

bit 16-set
When the rung is false:

bits 14-15- retained if it was set

bit 16-reset