Rockwell Automation 2711 PanelBuilder Software Getting Started User Manual

Page 33

Advertising
background image

3–7

Overview of Sample Application

Publication 2711-6.2

DH-485 or DH+ Application Tags

This section defines the GS project tags that are used by the DH-485
or DH+ application.

For a DH-485 application, these tags read or write data to bit or
integer files associated with an SLC 500 controller.

For a DH+ application, these tags read or write data to bit or
integer files associated with an SLC 500 or PLC 5/25 controller.

GS Project Tags for DH-485 or DH+ Application

This object

Uses this tag

To

Motor_Start
Motor_Start_Ind

Start the motor by setting bit B3:0/0 ON (1).

Control state change by monitoring bit B3:0/4.

Motor_Stop
Motor_Stop_Ind

Stop the motor by setting bit B3:0/1 OFF (0).
Control state change by monitoring bit B3:0/5.

Motor_Stop_Ind

Display the current status (START or STOP) of
the motor by reading bit B3:0/5.

Motor_AutoManual

Set the motor to AUTO or MANUAL mode by
writing an unsigned integer value to N7:0.

Motor_AutoManual

Display the current mode (AUTO or MANUAL)
of the motor by reading the data at N7:0.

Motor_Speed

Enter a new motor speed (0 to 1000 rpm) by
writing an unsigned integer value to N7:1.

Motor_Speed_Ind

Display the current motor speed in a graphic
form by reading the data at N7:2.

Motor_Speed_Dec

Decrease the motor speed by setting bit B3:0/3
ON (1) and OFF (0).

Motor_Speed_Inc

Increase the motor speed by setting bit B3:0/2
ON (1) and OFF (0).

Messages

Trigger a message to appear in the Alarm
Banner by reading the trigger value at N7:3.