Overview of tags – Rockwell Automation 2711 PanelBuilder Software Getting Started User Manual

Page 85

Advertising
background image

6–2

Entering the Application Tags

Publication 2711-6.2

The following tables list tag data for:

DH-485/DH+ applications communicating with an SLC or PLC
controller. The tag data is the same for these applications.

For DH+ applications communicating with a PLC, it is okay to
leave SLC_1 in the Node Name field.

Remote I/O application communicating with a PLC controller

Refer to the appropriate table when entering tags in the next section.

Tags for DH-485 or DH+ Getting Started Application (Project GS)

Tag Name

Data Type

Description

Node Name

(Controller)

Tag

Address

Initial

Value

Update

Frequency

Messages

Unsigned Integer

Displays alarm messages.

SLC_1

N7:3

0

1

Motor_AutoManual

Unsigned Integer

Motor auto/manual indication.

SLC_1

N7:0

0

1

Motor_Speed

Unsigned Integer

Controls motor speed.

SLC_1

N7:1

0

1

Motor_Speed_Dec

Bit

Decrements motor speed.

SLC_1

B3:0/3

0

1

Motor_Speed_Inc

Bit

Increments motor speed.

SLC_1

B3:0/2

0

1

Motor_Speed_Ind

Unsigned Integer

Indicates motor speed.

SLC_1

N7:2

0

1

Motor_Start

Bit

Starts motor.

SLC_1

B3:0/0

0

1

Motor_Start_Ind

Bit

Motor start indication.

SLC_1

B3:0/4

0

1

Motor_Stop

Bit

Stops motor.

SLC_1

B3:0/1

0

1

Motor_Stop_Ind

Bit

Motor stop indication.

SLC_1

B3:0/5

0

1

Tags for Remote I/O Getting Started Application (Project GSRIO)

Tag Name

Data Type

Description

Node Name
(Controller)

Tag

Address

Initial

Value

Update

Frequency

Messages

Unsigned Integer

Displays alarm messages.

PLC_RIO

N7:4

0

1

Motor_AutoManual

Unsigned Integer

Motor auto/manual indication.

PLC_RIO

N7:10

0

1

Motor_AutoMan_Ind

Unsigned Integer

Motor auto/manual status
indication.

PLC_RIO

N7:3

0

1

Motor_Spd_Handshk

Bit

Motor speed handshake.

PLC_RIO

N7:2/2

0

1

Motor_Spd_Notify

Bit

Motor speed notification.

PLC_RIO

N7:11/4

0

1

Motor_Speed

Unsigned Integer

Controls motor speed.

PLC_RIO

N7:13

0

1

Motor_Speed_Dec

Bit

Decrements motor speed.

PLC_RIO

N7:11/0

0

1

Motor_Speed_Inc

Bit

Increments motor speed.

PLC_RIO

N7:11/1

0

1

Motor_Speed_Ind

Unsigned Integer

Indicates motor speed.

PLC_RIO

N7:1

0

1

Motor_Start

Bit

Starts motor.

PLC_RIO

I:010/10

0

1

Motor_Start_Ind

Bit

Motor start indication.

PLC_RIO

O:010/10

0

1

Motor_Stop

Bit

Stops motor.

PLC_RIO

I:010/11

0

1

Motor_Stop_Ind

Bit

Motor stop indication.

PLC_RIO

O:010/11

0

1

Overview of Tags