Chapter 5
Auto Setup

5–21

If the number of sample images specified in the

Configure

Teach Count

menu item is greater than 0 (because you set

Teach Count

to the number of

samples to be used for part teaching), the following message will appear in
the message box:

The system will now acquire 35 images for part
teaching. The machine must run good blisters
during this procedure. Select Continue to
proceed. Select Stop to abort auto–setup.

At this point, your production equipment should be set up to inspect the
appropriate number of samples (35, in the above example).

When you pick

Continue

, the system acquires the first part–teaching image

(similar to Figure 5.7). The menu bar changes as shown in Figure 5.9:

Figure 5.9
Menu Bar for Parts Teaching Operations

At the same time, the message box contains a message such as this (if the
acquired image is O.K.):

Acquired image. Accept or reject.
0 of 35 images accepted.

You can proceed by picking one of the following menu items:

Accept All

–– Pick this menu item if you want the system to inspect the

entire set of samples without waiting for your approval of each sample.
The system will acquire a new image with each trigger signal. (However,
if any image cannot be used because it contains an incorrect number of
objects, the system will stop inspecting, and will wait for you to pick the

Reject

menu item before proceeding).

Accept

–– Pick this menu item if you want the system to inspect the

samples one–at–a–time and pause after acquiring each image. You must
then pick

Accept

,

Reject

, or

Accept All

, whichever is appropriate, to

acquire the next image.

Reject

–– Pick this menu item if you want the system to reject an

acquired image. (Note that you must pick

Reject

if the system finds an

image that contains an incorrect number of objects.)